Ideal

NAVI Load Box / Equipment


Test Equipment for Instrument Transformer


GET ACRO
You need Acrobat ReaderJ to see PDF files.
If you don't have it, please download.

Test Equipment for Instrument Transformer (Transportable)

DAC-VCTT-6

DAC-VCTT-6

DAC-VCTT-6 is a Current-Comparator-type Transformer Bridge for testing ratio errors and phase angles of instrument transformers (VT/CT).
This set alone enables users to test Current Transformers (CT) and Voltage Transformers (VT).
It is transportable and suitable for on-site tests.
PDF
TOP縺ク謌サ繧・ border=

Test Equipment for Instrument Transformer

DAC-VCTT-8

DAC-VCTT-8

DAC-VCTT-8 is a test set, provided with an automatic-current comparator-type transformer, for measuring ratio errors and phase angles of instrument transformers according to the international standards IEC 60044-1 and -2. Combining an optional different-ratio adapter, DAC-RAC-2/RAV-2, minimum reference standard instrument transformers are required. Internal burden is as small as 0.1VA.
PDF
TOP縺ク謌サ繧・ border=

Optional Ratio Adapter for DAC-VCTT-7

DAC-RAC-2/RAV-2

DAC-RAC-2/RAV-2

By connecting this ratio adapter to DAC-VCTT-8, even though there is a different transformation ratio between a standard and a test specimen, the test is possible.
PDF
TOP縺ク謌サ繧・ border=

Error Test Equipment for Transformer with Electronic Circuit

DAC-VTC-6/CTC-6

DAC-VTC-6/CTC-6

DAC-VTC-6/CTC-6 is a test set for measuring ratio errors and phase angles of instrument transformers CT/VT that have very small rated secondary currents & voltages with power meters and watthour meters. Since it has the absolute measurement mode to test specimens themselves without any standards, it is suitable for measurement of prototypes.
TOP縺ク謌サ繧・ border=

Electronic Load Equipment for Instrument Transformer

DAC-PBVC-8

DAC-PBVC-8

DAC-PBVC-8 is a burden device for error tests of instrument transformers (VT/CT).
This new device features combination of real loads, made by resistance and reactance, and electronic AC loads.
You can set up ideal loads (including zero load) by means of detecting internal burden of error test equipment and impedance of connecting cables.
It is possible to test CT up to 200VA and VT up to 500VA by connecting the optional increase burden box.
PDF
TOP縺ク謌サ繧・ border=

Transformer Fixed Burden Box

nothing

This fixed burden is for instrument transformers.
And you can select two types: for current transformers and for voltage transformers.
TOP縺ク謌サ繧・ border=

Standard Current Transformer/ Voltage Transformer

nothing

These transformers are used as standard to test instrument transformers.
TOP縺ク謌サ繧・ border=

Simple Ratio Meter for Voltage Transformer

DAC-RT-3

DAC-RT-3

DAC-RT-3 is a measuring instrument for testing ratio error of power transformers and instrument transformers.
The operation is simple because of touch panel method; it is transportable and suitable for onsite tests.
PDF
TOP縺ク謌サ繧・ border=
Japanese