Ideal

NAVI Measuring Equipment Calibrator Peripheral Equipment


Partial Discharge Measuring Equipment


GET ACRO
You need Acrobat ReaderJ to see PDF files.
If you don't have it, please download.
PDF
DAC-PD series catalog

Partial Discharge Measuring Equipment

DAC-PD-3

DAC-PD-3

DAC-PD-3 has two modes of Wide Band and Low Frequency. You can use it for Partial Discharge tests of High-Voltage Equipment, Insulation Materials, High-Frequency Equipment, and Power Semiconductor devices.

- High Voltage Equipment
(Generators, Rotating Machines, Armatures, Transformers, and Cables)
- Stator Coils
- Insulation Materials
- Power Semiconductor Devices
- High Frequency Equipment
PDF
TOP
DAC-PD-5

DAC-PD-5

DAC-PD-5 is suitable for on-site Partial Discharge tests of GIS (Gas Insulated Switchgears), Transformers, and Rotating Machines.
You can select a center frequency and the bandwidth. Therefore DAC-PD-5 can detect the Partial Discharge in a certain bandwidth at a given frequency, while conventional measuring instruments have fixed frequency bands to measure.
TOP
DAC-PD-7

DAC-PD-7

DAC-PD-7 is designed to reduce complicated tasks (calibration, wiring, and evaluation) with Partial Discharge (PD) measurements, so that can test PD promptly and easily without the expert knowledge.
DAC-PD-7 alone allows all of the tests on PD without peripheral equipment.
DAC-PD-7 can easily realize the test of PD on print-circuit boards, connectors, semiconductors, small motors and other insulation materials, to make a judgment on good / bad of them.
PDF
TOP

No corona variable frequency pressure test power supply

DAC-WT-25/50

DAC-WT-25/50

DAC-WT-25/50 is a testing power supply for Withstand Voltage and Partial Discharge measurements, witch features corona-free and variable-frequency design.
The partial discharge at a rated voltage is restrained less than 1pC, and the output frequency can be set from 46Hz to 1kHz (10kHz as optional design). The adoption of a linear amplifier enables the extremely small distortion of output waves, and the precision voltage can be applied to specimens.
TOP

Calibrator

DAC-CP-2

DAC-CP-2

DAC-CP-2 is a calibrator for partial discharge measurements.
The electric charge enables to generate up to max 10000pC.
It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
TOP

Calibrator Pulse Generator

DAC-CP-100

DAC-CP-100

- Output Voltage: 10V, 30V, 100V
- Risetime: 30ns, 1, 2, 5μs
- Generating Charge: 0 - 10000pC
- Repetitive Frequency: 50/60Hz (synchronized with Power Supply)
- Power Supply: AC100V 50/60Hz
- Dimension: W260*H149*D350 (mm)
- Weight: 5kg
TOP

High frequency CT

I-125

I-125-1A

- Outside Diameter (mm): 80φ x 35t
- Inside Diameter (mm): 34φ
- Frequency Band: 10kHz - 100MHz
- Output Impedance: 50Ω
- Output Connector: N type (available for BNC converting plugs)
TOP

Partial Discharge Detecting Box

DAC-PDB-2

DAC-PDB-2

DAC-PDB-2 is an all-in-one unit consisting of Detector (DAC-PDE-2), the Blocking Coil, and the Coupling Capacitor.
The rated voltage is AC12kV. It is the portable detecting unit because of small and light (7kg).
TOP

Blocking Coil & Coupling Capacitor

DAC-LCC-15/30/50

DAC-LCC-15/30/50

DAC-LCC-15/30/50 is all in one and weight saving by combining the high-inductance Blocking Coil with the Coupling Capacitor.

You can select the followings correspond to using voltages.

- Model - Rated Voltage
DAC-LCC-15 AC15kV
DAC-LCC-30 AC30kV
DAC-LCC-50 AC50kV
TOP
Japanese